MINERALS & CHEMICALS PHILIPP CORPORATION, PLAINTIFF-APPELLEE,
v.
S. S. NATIONAL TRADER, HER ENGINES, BOILERS, ETC., AND ORTEGAL COMPANIA NAVIERA S. A., DEFENDANT-APPELLANT, AND EXCELSIOR SHIPPING CO., LTD., DEFENDANT
AI-generated. These summaries, headnotes, and key points are machine-generated and may contain errors or omissions. Always verify against the full opinion text below. Not legal advice.
The court held that the trial court's findings regarding the cause of the fire were supported by sufficient evidence, including expert testimony and circumstantial evidence, and were not clearly erroneous.
Plaintiff's cargo was destroyed by a fire on a ship. The plaintiff's expert testified that the fire was caused by the defendant's design or negligent …
The full statement of facts, procedural history, and disposition for this case are member content.
Join FLexlaw to unlock all legal intelligence© FLexlaw, Inc. — AI-generated enrichments are proprietary. All rights reserved.
Explore caselaw by topic → Browse Expert Testimony cases and more on FLexlaw
PER CURIAM:
The principal issue here is factual: whether the evidence supports the finding by the court below that defendant Ortegal’s design, or negligent use and repair of its port boiler, caused ignition of oil fumes from the port settling tank resulting in a fire which destroyed plaintiff’s cargo. Defendant’s principal contention on appeal is that the only real evidence of the cause of the fire rested on hearsay statements, improperly admitted by the trial court, sitting without a jury.
It is true that plaintiff’s expert Thompson, who examined the ship after the fire, did in arriving at his conclusions read statements of certain crew members, but he did so in lieu of reading the log book which was destroyed by the fire itself. His testimony as to the 27“ proximity of the port boiler and the port' side settling tank was, however, based on defendant’s plan. He actually saw after the fire that there was no valve on the depth gauging device of the port settler and no can at the end of the valve. Defendant Ortegal’s own evidence was to the effect that the second engineer had installed several months before the fire a small pipe at the 15 foot level of the settling tanks, to keep a cheek on them. This pipe permitted oil to drain and drip out at the bottom of the pipe line. There was substantial evidence that vapors from fuel oil could accumulate in the area of the outlet of such a pipe which operated as an air vent. On internal examination, after the fire to be sure, Thompson also observed bowed or bulged brick work toward the center of the port boiler furnace. His opinion that this buckling was caused prior to the main fire rested on his not finding any “similar serious damage” to the various pipes, fittings and valves in the area of the boiler casing. He did state as one of the reasons for his opinion on the sequence of the buckling and the main fire that the heat in the 8-foot space between the boiler easing and the bulkhead was “practically unbearable,” according to “one of the engineer’s testimonies [sic].” But Thompson also stated that from his experience he was of the view that the external fire which is the subject of this litigation could not have caused the bowing of the brick work. On cross he testified that “the condition of the plating bore out the fact that it had been excessively overheated and buckled in that area.” Thus, the conclusion was supported without reference to hearsay in the form of the “engineer’s testimonies.” Sayen v. Rydzewski, 387 F. 2d 815, 819 (7th Cir. 1967); see 2 Wigmore, Evidence § 678 (3rd ed. 1940).
The conclusions of Thompson were also corroborated and substantiated by other expert testimony of the witnesses Wright and Parker. By the very nature of a fire, its cause must often be proven through a combination of common sense, circumstantial evidence and expert testimony. United States v. Ebinger, 386 F. 2d 557, 560 (2d Cir. 1967). See also Michalic v. Cleveland Tankers, Inc., 364 U.S. 325, 330, 81 S.Ct. 6, 5 L.Ed.2d 20 (1960); The Slavers (Reindeer), 69 U.S. (2 Wall.) 383, 401, 17 L.Ed. 911 (1864) (when “positive proof * * * is not generally to be expected, * * * the law allows a resort to circumstances * * *"); 7 Wigmore, Evidence § 1976 (3rd ed. 1940).
We cannot say as a matter of law that the trial court’s findings here were based on insufficient evidence or were clearly erroneous. Rule 52(a), Fed.R.Civ.P. Judgment affirmed.
Cases With Similar Vibessemantic neighbors from the corpus
Citator
Cited By
-
In re the complaint of the United States v. Standard OIL Co. OF Cal., 495 F.2d 911 (9th Cir. 1974)
-
Hal Korek and Charlotte Korek v. United States, 734 F.2d 923 (2d Cir. 1984)
Authorities Cited
- Michalic v. Cleveland Tankers, Inc., 364 U.S. 325 (U.S. 1960)
- The Slavers. (Reindeer.), 2 Wall. 383 (U.S. 1864)
- United States v. Tobias Ebinger, 386 F.2d 557 (2d Cir. 1967)
- Sayen v. Rydzewski, 387 F.2d 815 (7th Cir. 1967)